World only small Perfusion-SUB integrating HFF, SUS and O-SUP
Missing pre-assembled Single-Use-Bioreactor for perfusion? Take advantage of the Pulsating-Tangential-Flow (PTF) concept integrating Single-Use-Bioreactor (SUB), the Clio diaphragm One-way-Single-Use-Pump (O-SUP) with single-use Hollow-Fiber-Filter (HFF) and Single-Use-Sensor's (SUS).
From left: 1. – WORLD only 100 % pre-assembled and single-use assembly, 2. Packed, pre-sterilized and ready to use Single-Use-Bioreactor for perfusion, 3. Rendered assembly incl Single-Use-Pump all ready to use.
CellMembra-3200 integrates SUB / O-SUP / HFF / SUS in one package:
- 3,2 liter Vessel Volume (VV) with 5 x PG 13,5 ports supplied by CerCell
- 0,4 – 2,0 liter Working Volume (WV)
- Integrated Single-Use-Sensor - OneFerm or FermProbe pH and VisiWell or PolarWell for standard DO Re-Usable-Sensor's
- 3 free PG 13,5 port for other sensor's
- O-SUP is Clio-100 with fully controlled and measured broth volume and velocity - see O-SUP spec
- Thermal control either electrical or with water - check out under Thermal Accessories
HFF - most often used
- A. Spectrum HFF with 0,2 µm pore, 14 x 1,0 mm straw/lumen, 290 cm2 area, Luer-Lok side ports, (T06-P20U-10-N)
- B. Spectrum HFF with 0,2 µm pore, 75 x 1,0 mm straw/lumen, 980 cm2 area, 3/4" TC side ports, (S04-P20U-10-N)
- C. GE filters
Clio-100 diaphragm O-SUP controlled by:
- The ultra compact Clotho Drive Unit available in both a single channel and a dual channel version
- If you don't have 3-4 Bar pressure and good vacuum supply available in your lab - then add one or two of the Alagonia pumps and one Sarpedon reservoir
ESACT presentation CellMembra
CellMembra Clio-100 on foot
Clotho tower CellMembra on MST
From left: 1. – Working presentation on ESACT in Lausanne. 2. – Incl Clio-100 O-SUP and the support foot which also holds the red laser sensor. 3. – One example of SUB supporting hardware installation showing Clotho, Alagonia, Sarpedon.
SUS - Single-Use-Sensor’s to choose from:
- One port for either PolarWell or VisiWell Single-Use-Well (SUW) for 220 mm RUS
- One port for OneFerm or FermProbe pH Single-Use-Sensor (SUS) S8 socket, classical signal
- PICO bio-mass sensor optional installed horizontal at bottom
- One port for thermo couple
- Reduce vastly or eliminate components sterilized in conventional autoclave
Other features for the 3200 P-SUB:
- Fully assembled Perfusion-SUB packed in dual film bags and precision irradiated - ready to use
- Limited need for assembling the perfusion concept in LAF bench – less contamination risks - bio-mass SUS is also possible
- Three baffles of width 10 mm x thickness 4 mm – if you have other requirements – tell us
- Impeller: Kidney impeller, OD 60 mm, 3 blades, 30 degrees clock wise rotation and up flow mounted 50 mm from the bottom – if you have other requirements – tell us
- Pumped volume and velocity measured accurately and fully controlled – no guessing
More information about CellMembra P-SUB to be found under Support