Clio O-SUP keep the HFF clean in TFF mode

Clio O-SUP keep the HHF clean as to sequential selectable fluid velocities  

Clio is a fluid conveying OneWay-Single-Use-Pump (O-SUP) and part of CellMembra perfusion concept. Build for super controlled operation by the advanced Clotho or Lachesis Drive Units.

Clotho measures via the LASER accurately in real-time the free-flowing diaphragm position. Allowing software the desired volume to convey and at desired fluid velocity. The result is an Air-Operated-Diaphragm-positive-Displacement (AODPD) OneWay-Single-Use-Pump (O-SUP) with un-parallel performance.

M80 2024 01 25 192038Clio DCM80 60 BIVH 01 Centered Section ViewCM80 60 BIVH 01 01CM80 60 BIVH 01 03CM80 60 BIVH 01 02

Scalable - YES - check out spec table

Clio O-SUP models

CM80/40

CM80

CM100

CM140

CM200

Availability

     

     

     

      

      

Layout, number of diaphragms

single

single

single

single

single

Diaphragm diameter, mm

80

 80

 100

 140

 200

Stroke Volume, SV, mL/S, 100% stroke

40

60

200

500

1,200

Cardiac Output (CO range), harvest cycle, max mL/min

225

450

1,500

2,500

9,500

Beats-per-Minute, BpM

0-18

0-18

0-15

0-10

0-8

Choose from one of various feed connections

HFF integrated or Luer-Loc or barb

HFF integrated or barb or TRI-flange

HFF integrated or barb or TRI-flange

HFF integrated or TRI-flange 1½”

HFF integrated or TRI-flange Tri 3”

Drive Unit

Clotho

Clotho

Clotho

Lachesis

Atropos

Clio technical / functionality

  • The diaphragm OneWay-Single-Use-Pump (O-SUP) integrates two passive OneWay valves guiding the direction of fluid. The valve body receives broth from the SUB and deliver broth to the Hollow-Fiber-Filter (HFF) feed inlet after which the broth passes axially the HFF and exit as retentate to be returned to the SUB
  • Clio O-SUP integrates between the SUB and the HFF
  • Clio features the re-usable (red) LASER sensor reading diaphragm position through the transparent dome window = know the position = optimum position programming
  • As the position of the diaphragm is know at any time the broth velocity and volume calculation can be performed, repeated and presented on the Clotho display in real-time 
  • Clio both pump and measures conveyed volume ranging within its spec and from 0 to >10 m/s velocity through the HFF

Left photo show several Clio size CM80 on two legged support and red LASER sensor support. Center photo CM80 mounted with Laser sensor support on top of dome and direct HFF coupling – NO Luer-Loc. Right photo show Clotho drive units connected to the small M80 O-SUP.

Unique user features:

  • Clio keep the HFF - Hollow-Fibre-Filter - clean from fouling issues maximizes process time
  • Clio handle fluids = liquids and / or gases or any mix of liquid/gas
  • Clio is a true metering feed pump = Positive Displacement (PD) pump = accurate mass-flow measured constantly
  • Clio pump do NOT need a mass-flow sensor measuring the mass-flow
  • Clio easily sucks fluids from low arranged containers
  • Clio is a low shear force, gentle design which do not damage mammalian cells
  • Clio pump do NOT need calibration like peristaltic pumps - Clio is self calibrating
  • Clio pump do NOT loose nano size silicone particles to the fluid like peristaltic pumps

The basics in operation is copied from the human heart functionality

  • Cardiac Output (CO) = total pumped volume, SUP capacity, mL/min (CO = BpM x SV)
  • Beats-per-Minute (BpM) = ranging 0 - 15 BpM, SUP diameter/stroke volume depending
  • Stroke Volume (SV) = programable from 0 - 100% of SUP capacity

Physical features:

  • No expensive housing materials for traditional steam cleaning requirements
  • No mechanical rotating parts such as electrical motor, coupling, rollers or gearing
  • Stationary passive silicone valves or moving ball valves
  • All single-use medical grade plastic parts supplied irradiated – contamination not possible
  • All pumps offer infinite turn-down, turn-up scale better than 1:5.000

Check out under Support and Download