TFF Integrated Clio™ master any fluid velocity accurately which keep the HFF clean 

Clio is a fluid conveying OneWay-Single-Use-Pump (O-SUP) and part of CellMembra TFF-Integrated perfusion concept (series 30 P-SUBs) . Build for super accurate operation by the advanced Clotho or Lachesis Drive Units.

Clotho measures via the LASER accurately in real-time the free-flowing diaphragm position. Allowing software to decide volume to be convey and at desired fluid velocity. The result is an Air-Operated-Diaphragm-Positive-Displacement (AODPD) OneWay-Single-Use-Pump (O-SUP) with un-parallel performance.

M80 2024 01 25 192038Clio DCM80 60 BIVH 01 Centered Section ViewCM80 60 BIVH 01 01CM80 60 BIVH 01 03CM80 60 BIVH 01 02

Scalable - YES - check out spec table

Clio O-SUP models

CM60

CM80

CM100

CM140

Availability

   

     

     

      

Diaphragm diameter, mm

60

 80

 100

 140

Stroke Volume, SV, mL/S, 100% stroke

20

50

200

500

Cardiac Output (CO range), harvest cycle, max mL/min

160

450

1,500

2,500

Beats-per-Minute, BpM

0-18

0-18

0-15

0-10

SUP and HFF connected

integrated

integrated

integrated

integrated

Drive Unit

Clotho

Clotho

Clotho

Lachesis

Clio technical / functionality

  • The diaphragm OneWay-Single-Use-Pump (O-SUP) includes two passive OneWay valves guiding the direction of fluid. The valve body receives broth from the P-SUB and deliver broth to the Hollow-Fiber-Filter (HFF) feed inlet after which the broth passes axially the HFF and exit as retentate to be returned to the P-SUB
  • Clio O-SUP is arranged between the P-SUB and are Integrated with the HFF
  • Clio features the re-usable (red) LASER sensor reading diaphragm position through the transparent dome window = know the position = optimum position programming
  • As the position of the diaphragm is known at any time the broth velocity and volume calculation can be performed, repeated and presented on the Clotho display in real-time or by Lucullus
  • Clio both pump and measures conveyed volume ranging within its spec and from 0 to >10 m/s velocity
  • The high precision LASER sensor measures constantly and accurate the position of the diaphragm, allowing Clotho, Lachesis, Atropos software to display desired conditions for exchanged broth volumes and velocities in real-time
  • Drive Units measure, facilitate and control the HFF pressure drop / DeltaP / ∆P initiating the cleaning cycle.

Left photo show Clio Integrated with BioBlu 0.3 with red LASER sensor support. Center photo CM80 mounted Integrated on vessel side – NO TC or Luer-Loc - HFF Integrated on Clio. Right photo show CellMembra TFF-Integrated chart.

Unique user features:

  • Clio keep the HFF, Hollow-Fibre-Filter clean from fouling issues maximizes process time
  • Clio handle fluids = liquids and / or gases or any mix of liquid/gas
  • Clio is a true metering pump = Positive Displacement (PD) pump = mass-flow measured accurately and constantly 
  • Clio pump do NOT need a mass-flow sensor measuring the mass-flow
  • Clio easily sucks fluids from low arranged containers
  • Clio is a low shear force, gentle design which do not damage mammalian cells
  • Clio pump do NOT need calibration like peristaltic pumps - Clio is self calibrating via intelligent software in Clotho, Lachesis
  • Clio pump do NOT loose nano size silicone particles to the fluid like peristaltic pumps

The basics in operation is copied from the human heart functionality

  • Cardiac Output (CO) = total pumped volume, SUP capacity, mL/min (CO = BpM x SV)
  • Beats-per-Minute (BpM) = ranging 0 - 20 BpM, SUP diameter/stroke volume depending
  • Stroke Volume (SV) = programmable from 0 - 100% of SUP capacity

Clio Single-Use-Pump chamber are manufactured from medical grade Nylon. The diaphragm is manufactured from medical grade silicone. The two valves are manufactured from medical grade silicone. Platinum cured silicone or M-Flex in the dimension and length you may desire. 

Check out under Commerce and Support and Download manuels